ATE-2 Handheld CalibratorThe Ashcroft® ATE-2 handheld calibrator is an exceptional instrument performing precision measurement of pressure, temperature, current or voltage
|
||
Pressure Measurement Accuracies | Pressure Types | Pressure Ranges |
---|---|---|
±0.025, 0.05 and 0.1% of span | Gauge, compound, vacuum, absolute and differential | 0/0.25 in H20 through 10,000 psi |
ATE-2 Handheld Calibrator
The Ashcroft® ATE-2 handheld calibrator is an exceptional instrument performing precision measurement of pressure, temperature, current or voltage. The base unit includes application-specific firmware for convenient instrument calibration and logging of associated data. In addition, the ATE-2 has the ability to interface the system with a computer, data acquisition system or dumb terminal via the standard USB interface. An ideal product when calibration and traceability are needed. Key Features:
Specifications:
|
PT-1 Pressure TesterThe Ashcroft® PT-1 bench-top calibrator is used and measurement applications requiring very high accuracy secondary transfer standards.
|
||
Pressure Measurement Accuracies | Pressure Types | Pressure Ranges |
---|---|---|
±0.025, 0.05 and 0.1% of span | Gauge, compound, vacuum, absolute and differential | 0/0.25 in H20 through 0/10,000 psi |
PT-1 Pressure Tester The Ashcroft® PT-1 bench-top calibrator is used on measurement applications requiring highly accurate secondary transfer standards. The PT-1 includes 1 or 2 permanently installed pressure or temperature sensors. Key Features:
Specifications:
|
ST-2A Digital IndicatorThe Ashcroft® ST-2A bench top (or panel mounting) calibrator shares the same pressure and temperature modules and interfaces as the Ashcroft ATE-100..
|
||
Pressure Measurement Accuracies | Pressure Types | Pressure Ranges |
---|---|---|
±0.025, 0.05, and 0.1% of span | Gauge, compound, vacuum, absolute and differential | 0/0.25 in H20 through 0/10,000 psi |
Data sheet |
ST-2A Digital Indicator The Ashcroft® ST-2A bench top (or panel mounting) calibrator shares the same pressure and temperature modules and interfaces as the Ashcroft ATE-100. It uses the AQS modular sensor system to provide the ultimate in measurement flexibility. The base unit contains a wide variety of application-specific firmware as well as the ability to measure both current and voltage inputs. In addition, this unit has the ability to interface the system with a computer, data acquisition system or dumb terminal via the standard RS232 interface. Key Features:
Specifications:
|
ATE-100 Handheld CalibratorThe Ashcroft® ATE-100 handheld calibrator is an exceptional instrument performing precision measurement of pressure (psi/psid), temperature, current or voltage. |
||
Pressure Measurement Accuracies | Pressure Types | Pressure Ranges |
---|---|---|
±0.025, 0.05, and 0.10% or .06/.07% | Gauge, compound, vacuum, absolute and differential | 0.25 in H20 to 10,000 psi |
Data Sheet |
ATE-100 Handheld Calibrator The Ashcroft® ATE-100 handheld calibrator is an exceptional instrument Key Features:
Specifications:
|